Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Front Cell Infect Microbiol ; 14: 1371695, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38638823

RESUMO

Introduction: SARS-CoV-2 vaccines production and distribution enabled the return to normalcy worldwide, but it was not fast enough to avoid the emergence of variants capable of evading immune response induced by prior infections and vaccination. This study evaluated, against Omicron sublineages BA.1, BA.5 and BQ.1.1, the antibody response of a cohort vaccinated with a two doses CoronaVac protocol and followed by two heterologous booster doses. Methods: To assess vaccination effectiveness, serum samples were collected from 160 individuals, in 3 different time points (9, 12 and 18 months after CoronaVac protocol). For each time point, individuals were divided into 3 subgroups, based on the number of additional doses received (No booster, 1 booster and 2 boosters), and a viral microneutralization assay was performed to evaluate neutralization titers and seroconvertion rate. Results: The findings presented here show that, despite the first booster, at 9m time point, improved neutralization level against omicron ancestor BA.1 (133.1 to 663.3), this trend was significantly lower for BQ.1.1 and BA.5 (132.4 to 199.1, 63.2 to 100.2, respectively). However, at 18m time point, the administration of a second booster dose considerably improved the antibody neutralization, and this was observed not only against BA.1 (2361.5), but also against subvariants BQ.1.1 (726.1) and BA.5 (659.1). Additionally, our data showed that, after first booster, seroconvertion rate for BA.5 decayed over time (93.3% at 12m to 68.4% at 18m), but after the second booster, seroconvertion was completely recovered (95% at 18m). Discussion: Our study reinforces the concerns about immunity evasion of the SARS-CoV-2 omicron subvariants, where BA.5 and BQ.1.1 were less neutralized by vaccine induced antibodies than BA.1. On the other hand, the administration of a second booster significantly enhanced antibody neutralization capacity against these subvariants. It is likely that, as new SARS-CoV-2 subvariants continue to emerge, additional immunizations will be needed over time.


Assuntos
Vacina BNT162 , Vacinas contra COVID-19 , Vacinas de Produtos Inativados , Humanos , Anticorpos Antivirais , Imunização , SARS-CoV-2 , Anticorpos Neutralizantes
2.
Front Immunol ; 14: 1220600, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37520570

RESUMO

Introduction: The pandemic caused by SARS-CoV-2 has had a major impact on health systems. Vaccines have been shown to be effective in improving the clinical outcome of COVID-19, but they are not able to fully prevent infection and reinfection, especially that caused by new variants. Methods: Here, we tracked for 450 days the humoral immune response and reinfection in 52 healthcare workers from Brazil. Infection and reinfection were confirmed by RT-qPCR, while IgM and IgG antibody levels were monitored by rapid test. Results: Of the 52 participants, 19 (36%) got reinfected during the follow-up period, all presenting mild symptoms. For all participants, IgM levels dropped sharply, with over 47% of them becoming seronegative by the 60th day. For IgG, 90% of the participants became seropositive within the first 30 days of follow-up. IgG antibodies also dropped after this period reaching the lowest level on day 270 (68.5 ± 72.3, p<0.0001). Booster dose and reinfection increased the levels of both antibodies, with the interaction between them resulting in an increase in IgG levels of 130.3 arbitrary units. Conclusions: Overall, our data indicate that acquired humoral immunity declines over time and suggests that IgM and IgG antibody levels are not associated with the prevention of reinfection.


Assuntos
COVID-19 , Imunidade Humoral , Humanos , SARS-CoV-2 , Brasil/epidemiologia , Estudos Longitudinais , Reinfecção , Imunoglobulina G , Pessoal de Saúde , Imunoglobulina M
3.
Mem Inst Oswaldo Cruz ; 117: e220050, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35766650

RESUMO

BACKGROUND: Severe acute respiratory syndrome coronavirus (SARS-CoV-2) omicron variant was first detected in South Africa in November 2021. Since then, the number of cases due to this variant increases enormously every day in different parts of the world. Mutations within omicron genome may impair the molecular detection resulting in false negative results during Coronavirus disease 19 (COVID-19) diagnosis. OBJECTIVES: To verify if colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) targeting N and E genes would work efficiently to detect omicron SARS-CoV-2 variant and its sub-lineages. METHODS: SARS-CoV-2 reverse transcription quantitative polymerase chain reaction (RT-qPCR) positive samples were sequenced by next generation DNA sequencing. The consensus sequences generated were submitted to Pangolin tool for SARS-CoV-2 lineage identification. RT-LAMP reactions were performed at 65ºC/30 min targeting N and E. FINDINGS: SARS-CoV-2 omicron can be detected by RT-LAMP targeting N and E genes despite the genomic mutation of this more transmissible lineage. Omicron SARS-CoV-2 sub-lineages were tested and efficiently detected by RT-LAMP. We demonstrated that this test is very sensitive in detecting omicron variant, with LoD as low as 0.4 copies/µL. MAIN CONCLUSIONS: Molecular detection of omicron SARS-CoV-2 variant and its sub-lineages can be achieved by RT-LAMP despite the genomic mutations as a very sensitive surveillance tool for COVID-19 molecular diagnosis.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Genômica , Humanos , Técnicas de Diagnóstico Molecular/métodos , Mutação/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , SARS-CoV-2/genética , Sensibilidade e Especificidade
4.
Mem. Inst. Oswaldo Cruz ; 117: e220050, 2022. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1386350

RESUMO

BACKGROUND Severe acute respiratory syndrome coronavirus (SARS-CoV-2) omicron variant was first detected in South Africa in November 2021. Since then, the number of cases due to this variant increases enormously every day in different parts of the world. Mutations within omicron genome may impair the molecular detection resulting in false negative results during Coronavirus disease 19 (COVID-19) diagnosis. OBJECTIVES To verify if colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) targeting N and E genes would work efficiently to detect omicron SARS-CoV-2 variant and its sub-lineages. METHODS SARS-CoV-2 reverse transcription quantitative polymerase chain reaction (RT-qPCR) positive samples were sequenced by next generation DNA sequencing. The consensus sequences generated were submitted to Pangolin tool for SARS-CoV-2 lineage identification. RT-LAMP reactions were performed at 65ºC/30 min targeting N and E. FINDINGS SARS-CoV-2 omicron can be detected by RT-LAMP targeting N and E genes despite the genomic mutation of this more transmissible lineage. Omicron SARS-CoV-2 sub-lineages were tested and efficiently detected by RT-LAMP. We demonstrated that this test is very sensitive in detecting omicron variant, with LoD as low as 0.4 copies/µL. MAIN CONCLUSIONS Molecular detection of omicron SARS-CoV-2 variant and its sub-lineages can be achieved by RT-LAMP despite the genomic mutations as a very sensitive surveillance tool for COVID-19 molecular diagnosis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA